Reference electrode converter

Convert a structure potential measured against one reference electrode to its equivalent on the others.

Inputs

mV
Whole millivolts, negative for most protected structures.

Result

CSEyour reading −850 mV
Ag/AgCl (SW) −784 mV
Ag/AgCl (sat. KCl) −731 mV
Ag/AgCl (3 M KCl) −744 mV
SCE −775 mV
Zn (SW) +246 mV
SHE −534 mV
MEETS −850 mV CSE Equivalent of −850 mV vs CSE.

How it’s calculated

Each reference electrode sits at a known potential against the standard hydrogen electrode (SHE). Converting is a matter of adding the difference between the two electrodes.

E(to) = E(from) + E°(from) − E°(to)

where E° is each electrode’s potential against SHE. Values used in this tool, at about 25 °C:

ElectrodeE° vs SHE (mV)
Copper/copper sulfate (CSE)Saturated CuSO₄. The usual field reference for buried structures.+316
Silver/silver chloride, seawaterUsed in seawater; shifts with salinity.+250
Silver/silver chloride, saturated KCl+197
Silver/silver chloride, 3 M KCl+210
Saturated calomel (SCE)+241
Zinc, seawaterA working reference; less stable than the others.−780
Standard hydrogen electrode (SHE)0

Reference potentials shift with temperature and chloride content. [Verify these values against the chosen references before launch.]

Worked example

A diver reads a wharf pile against Ag/AgCl in seawater, but the criterion you know is −850 mV CSE. What is that criterion on Ag/AgCl?

E(Ag/AgCl) = −850 + 316 − 250
           = −784 mV

Published tables often round this to −800 mV. Small differences like this come from the reference potentials each source assumes.

References

  • [Standard or text the electrode potentials are taken from]
  • [Standard defining the protection criteria referred to]