Result
How it’s calculated
Each reference electrode sits at a known potential against the standard hydrogen electrode (SHE). Converting is a matter of adding the difference between the two electrodes.
E(to) = E(from) + E°(from) − E°(to)
where E° is each electrode’s potential against SHE. Values used in this tool, at about 25 °C:
| Electrode | E° vs SHE (mV) |
|---|---|
| Copper/copper sulfate (CSE)Saturated CuSO₄. The usual field reference for buried structures. | +316 |
| Silver/silver chloride, seawaterUsed in seawater; shifts with salinity. | +250 |
| Silver/silver chloride, saturated KCl | +197 |
| Silver/silver chloride, 3 M KCl | +210 |
| Saturated calomel (SCE) | +241 |
| Zinc, seawaterA working reference; less stable than the others. | −780 |
| Standard hydrogen electrode (SHE) | 0 |
Reference potentials shift with temperature and chloride content. [Verify these values against the chosen references before launch.]
Worked example
A diver reads a wharf pile against Ag/AgCl in seawater, but the criterion you know is −850 mV CSE. What is that criterion on Ag/AgCl?
E(Ag/AgCl) = −850 + 316 − 250
= −784 mV Published tables often round this to −800 mV. Small differences like this come from the reference potentials each source assumes.
References
- [Standard or text the electrode potentials are taken from]
- [Standard defining the protection criteria referred to]