Transformer-rectifier
TR-01
Control mode
Negative return
Sacrificial anodes
Al-Zn-In · 18 off
One anode per pile on steel stand-offs · −1050 mV Ag/AgCl
Water
Piles protected · instant-OFF Ag/AgCl
Protected—
Least negative—
Most negative—
—
Sacrificial anode system
Each pile carries its own aluminium alloy anode. The anode corrodes instead of the steel, and its current flows through the water mostly to the pile it is welded to.
It needs no power, but its output is limited by its driving voltage and the water's resistance.
Try brackish or estuarine water, or let the anodes run down.
Impressed current system
A rectifier on the deck drives current from MMO anodes hanging in the water between the piles. The current spreads out in all directions,
so piles near an anode get more than piles further away. Raise the output until every pile is protected, and watch the nearest piles for over-protection.
Every pile is bonded, and the negative return is balanced: a drain at each column, fed from the middle. Switch to a single drain to see why that matters.
Space power (ICCP) · ↑ ↓ setpoint · 1 2 system · L labels
Criteria: instant-OFF −800 mV Ag/AgCl or more negative, not below −1100 mV. Guidance only.